<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<?xml-stylesheet type="text/xsl" href="../../../styles/reactor.xsl" ?>
<!DOCTYPE TEI.2 SYSTEM "../../../dtds/teixlite.dtd" [
<!ENTITY % MurNBinstrumentation052252 SYSTEM "MurNBinstrumentation052252.ent" >
%MurNBinstrumentation052252;
]>

<TEI.2 id="MurNBinstrumentation052252">
<teiHeader>
<fileDesc>

<titleStmt>
<title type="245">Memorandum from N. Underwood, A. Waltner, and G. Webb to Clifford K. Beck</title>
<title type="gmd">Machine readable transcription</title>
<author>Underwood, N.</author>
<author>Waltner, A.</author>
<author>Webb, G.</author>
<respStmt>
<resp>Creation of machine-readable version:</resp>
<name>Russell S. Koonts</name>
<resp>Creation of digital images:</resp>
<name>Russell S. Koonts</name>
<resp>Conversion to TEI.2-conformant markup:</resp>
<name>Russell S. Koonts</name>
</respStmt>
</titleStmt>

<extent>ca. 9 kilobytes</extent>

<publicationStmt>
<publisher>NCSU Libraries</publisher>
<pubPlace>Raleigh, NC</pubPlace>
<idno type="ETC"> Modern English, MurNBinstrumentation052252</idno>
<availability>
<p>Available from: NC State University Archives</p>
<p>Publicly-accessible</p>
<p n="public">URL: http://www.lib.ncsu.edu/archives/etext/engineering/reactor/murray/</p>
</availability>
<date>3 November, 2000</date>
</publicationStmt>

<seriesStmt>
<p>Nuclear Reactor Digitization Project</p>
<p>Raymond L. Murray Reactor Project Notebook</p>
</seriesStmt>

<notesStmt>
<note>Illustrations have been included from the print version.</note>
<note>Scanned by Russell Koonts with Photoshop 5.0 software.</note>
</notesStmt>

<sourceDesc>
<biblFull>
<titleStmt>
<title>Memorandum from N. Underwood, A. Waltner, and G. Webb to Clifford K. Beck</title>
<author>N. Underwood</author>
<author>A. Waltner</author>
<author>G. Webb</author>
<respStmt>
<resp></resp>
<name></name>
</respStmt>
</titleStmt>
<editionStmt>
<p></p>
</editionStmt>
<extent>3 pp.</extent>
<publicationStmt>
<publisher></publisher>
<pubPlace></pubPlace>
<date></date>
<idno>Manuscript copy consulted UA 105.16</idno>
</publicationStmt>
<seriesStmt>
<p></p>
</seriesStmt>
<notesStmt>
<note></note>
</notesStmt>
</biblFull>
</sourceDesc>
</fileDesc>

<encodingDesc>
<projectDesc>
<p>Prepared for the North Carolina State University Science and Technology Electronic Text Center</p>
</projectDesc>
<editorialDecl>
<p>The lineation of the manuscript has been maintained and all end-of-line hyphens have been preserved.</p>
<p>Keywords in the header are a local Science and Technology Electronic Text Center scheme to aid in establishing analytical groupings.</p>
</editorialDecl>
<refsDecl>
<p> </p>
</refsDecl>
<classDecl>
<taxonomy>
<bibl>
<title>Library of Congress Subject Headings</title>
</bibl>
</taxonomy>
</classDecl>
</encodingDesc>
<profileDesc>
<creation>
<date>May 22, 1952</date>
</creation>
<langUsage>
<language id="en">English</language>
</langUsage>
<textClass>
<keywords>
<term></term>
</keywords>
<keywords>
<term>LCSH</term>
</keywords>
<keywords>
<term id="visual-work">manuscript</term>
<term id="format">24-bit color: 400 dpi</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<text id="MurNBinstrumentation052252T">

<front><div1 type="summary" n="1">
<head><hi rend="bold"><hi rend="center">Memorandum from N. Underwood, A. Waltner, and G. Webb to Clifford K. Beck</hi><lb/>
<bibl><abbr>Typescript</abbr><lb/> <extent>3 pp.</extent> <lb/><date value="1952-05-22">May 22, 1952</date><lb/> <idno rend="suppress">MurNBinstrumentation052252</idno></bibl></hi></head>
<p>

</p>
</div1>
</front>

<body>
<pb n=""/>
<p><seg><xref id="reactorlg/MurNBinstrumentation052252a.jpg" rend="new">
<figure entity="MurNBinstrumentation052252a"></figure></xref></seg></p>
<div1 type="memorandum" n="1">
<head><hi rend="italics">Reac Memo</hi></head>
<opener>
Submitted <dateline><date value="1952-05-22">May 22, 1952</date></dateline>
TO: <name type="person">Clifford K. Beck</name><lb/>
FROM: <name type="person">N Underwood</name>, <name type="person">A Waltner</name>, and G Webb<lb/>
CC:  Reactor Committee<lb/>
SUBJECT: Instrumentation requirements for Achieving Critical Mass</opener>

<p>These <orig reg="instrumentation">intrumentation</orig> requirements are of a dual nature. First,<lb/>
the instrumentation specifically needed for the technical<lb/>
operation of determining the critical mass. Secondly, the<lb/>
instrumentation required from the viewpoint of possible hazards<lb/>
which might arise from some accidental occurrence.
</p>
<p>The instrumentation falling in the first category is as follows-
<table>
<row><cell cols='2'>1. U<hi rend="sup">235</hi> pulse channel</cell><cell></cell></row>
<row><cell>2. BF<hi rend="sub">3</hi>  "  "</cell><cell></cell><cell></cell></row>
<row><cell cols='2'>3. BF<hi rend="sub">3</hi>  "  "</cell><cell>These have sluggish level trips</cell></row>
<row><cell cols='2'>4. BF<hi rend="sub">3</hi>  "  "</cell><cell></cell></row>
<row><cell cols='2'>5. B<hi rend="sup">10</hi> integrating channel</cell><cell></cell></row>
<row><cell cols='2'>6. B<hi rend="sup">10</hi>  "  "</cell><cell rows='2'>These have fast level trips and<lb/>are the primary safeties</cell></row>
<row><cell cols='2'>7. &#x03B3;   "  "</cell><cell></cell></row>
<row><cell cols='2'>8. Liquid level indicator</cell></row>
<row><cell cols='3'>9. Rod and shim position indicators</cell></row>
<row><cell cols='3'>10. Sampling and liquid transfer device</cell></row>
<row><cell cols='3'>11. Monitoring systems for the critical procedures</cell></row>
<row><cell>&#x00A0;</cell><cell>a. &#x03B1; monitor</cell><cell></cell></row>
<row><cell></cell><cell>b.  air monitor</cell><cell></cell></row>
<row><cell></cell><cell>c.  personnel monitors - </cell><cell>film n sensitive</cell></row>
<row><cell></cell><cell></cell><cell>film &#x0392;, &#x03B3; sensitive</cell></row>
<row><cell></cell><cell></cell><cell>dosimeter n sensitive</cell></row>
<row><cell></cell><cell></cell><cell>dosimeter &#x0392;, &#x03B3; sensitive</cell></row>
</table>
</p>
<p>In the second classification we have the following-
<list>
<item>1. Campus monitors installed in permanent locations</item>
<item>2. Stack monitor</item>
<item>3. Dust monitor</item>
<item>4. Mobile monitor</item>
<item>5. Alarm system</item>
<item>6. Gas masks (closed cycle)</item>
<item>7. Liquid monitor</item>
<item>8. Indium foils</item>
<item>9. Recombiner and gas disposal system</item>
</list></p>
<pb n="2"/>
<p><seg><xref id="reactorlg/MurNBinstrumentation052252b.jpg" rend="new">
<figure entity="MurNBinstrumentation052252b"></figure></xref></seg></p>
<p>Below are listed partial cost estimates-
<table>
<row>
<cell>1.</cell><cell>U<hi rend='sup'>235</hi> pulse chamber</cell><cell cols='2'>cost information unavailable</cell>
</row>
<row><cell></cell><cell><name type="corporate">Atomic <abbr expan="Instrument">Inst</abbr></name> 205B</cell><cell></cell><cell><hi rend="center">120.</hi></cell>
</row>
<row><cell></cell><cell>"  " 204B</cell><cell></cell><cell><hi rend="center">395.</hi></cell>
</row>
<row><cell></cell><cell>"  " 1010 scaler</cell><cell></cell><cell><hi rend="center">430.</hi></cell>
</row>
<row><cell></cell><cell>"  " 410 rate meter</cell><cell></cell><cell><hi rend="center">325.</hi></cell>
</row>
<row><cell></cell><cell>Keleket timer</cell><cell></cell><cell><hi rend="center">60.</hi></cell>
</row>
<row><cell></cell><cell>Cable and connectors</cell><cell></cell><cell><hi rend="center">(50)</hi></cell>
</row>
<row><cell></cell><cell>Level trip modification</cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell>2.</cell><cell>BF<hi rend="sub">3</hi><name type="corporate"> G.E</name>, or <name type="corporate">R C L</name></cell><cell></cell><cell><hi rend="center">130 or 105.</hi></cell>
</row>
<row><cell></cell><cell><name type="corporate">Nuclear <abbr expan="Instrument">Inst</abbr></name> 128 scaler</cell><cell></cell><cell><hi rend="center">525.</hi></cell>
</row>
<row><cell></cell><cell><name type="corporate">Atomic <abbr expan="Instrument">Inst</abbr></name> 410 rate meter</cell><cell></cell><cell><hi rend="center">325.</hi></cell>
</row>
<row><cell></cell><cell>Cable and connectors</cell><cell></cell><cell><hi rend="center">(50)</hi></cell>
</row>
<row><cell></cell><cell>Level trip modification</cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell>3.</cell><cell>Duplicate of 2</cell><cell></cell><cell></cell>
</row>
<row><cell>4.</cell><cell cols='2'>Duplicate of 2 except omit ratemeter</cell><cell></cell>
</row>
<row><cell>5.</cell><cell>B<hi rend="sup">10</hi> ionization chamber</cell><cell></cell><cell><hi rend="center">(400)</hi></cell>
</row>
<row><cell></cell><cell>Shop estimate from <name type="person">Mr. Morris</name></cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell></cell><cell>Quartz insulation from <name type="corporate">G E</name></cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell></cell><cell>Special alloy materials <name type="corporate">Dow</name></cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell></cell><cell cols='3'>Special B<hi rend="sup">10</hi> coating.. requires special <orig reg="technique">techinque</orig> involving<lb/>
induction heating with inter gas flow. It may be advisable<lb/>
to make arrangements with <name type="person">Gundlach</name> to have him coat our<lb/>
chambers. This cost cannot be estimated.</cell>
</row>
<row><cell></cell><cell>Pre amp</cell><cell></cell><cell><hi rend="center">(250)</hi></cell>
</row>
<row><cell></cell><cell>Level trip</cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell></cell><cell>Difference amp</cell><cell></cell><cell><hi rend="center">(50)</hi></cell>
</row>
<row><cell></cell><cell>Cabling</cell><cell></cell><cell><hi rend="center">(200)</hi></cell>
</row>
<row><cell></cell><cell>Pure lead shield</cell><cell></cell><cell><hi rend="center">(50)</hi></cell>
</row>
<row><cell>6.</cell><cell cols='2'>Duplicate of 5 except add 3 motors</cell><cell><hi rend="center">105.</hi></cell>
</row>
<row><cell cols='3'>7. Scintillation &#x03B3; channel. This has not been studied with<lb/>
sufficient care to make a sound estimate but it <orig reg="is">it</orig> believed<lb/>
that it will be of the order of</cell><cell><hi rend='center'>(1000)</hi></cell>
</row>
<row><cell>8.</cell><cell cols='2'>Liquid level indicator (see <name type="person">Lancaster</name>)</cell><cell></cell>
</row>
<row><cell>9.</cell><cell cols='2'>Rod and shim position indicators approximately<lb/>total</cell><cell><hi rend="center">(50)</hi></cell>
</row>
<row><cell>10.</cell><cell cols='2'>Sampling and liquid transfer (see <name type="person">Beck</name>)</cell><cell></cell>
</row>
<row><cell>11.</cell><cell cols='2'>Monitoring for critical procedures</cell><cell></cell>
</row>
<row><cell></cell><cell>2 &#x03B1; Zeuto</cell><cell></cell><cell><hi rend="center">750</hi></cell>
</row>
<row><cell></cell><cell>air monitor</cell><cell></cell><cell><hi rend="center">(100)</hi></cell>
</row>
<row><cell></cell><cell>personnel monitor per person</cell><cell></cell><cell></cell>
</row>
<row><cell></cell><cell>&#x00A0;2 film badge</cell><cell></cell><cell><hi rend="center">10.</hi></cell>
</row>
<row><cell></cell><cell>&#x00A0;2 dosimeters &#x0392;, &#x03B3;</cell><cell></cell><cell><hi rend="center">25.</hi></cell>
</row>
<row><cell></cell><cell>&#x00A0; " neutron</cell><cell></cell><cell><hi rend="center">50.</hi></cell>
</row>
<row><cell></cell><cell cols='2'>use reading devices already have</cell><cell></cell>
</row>
</table></p>

<pb n="3"/>
<p><seg><xref id="reactorlg/MurNBinstrumentation052252c.jpg" rend="new">
<figure entity="MurNBinstrumentation052252c"></figure></xref></seg></p>
<p>
<table>

<row><cell cols='2'>1. Campus monitors installed in permanent</cell><cell>(1200)</cell>
</row>
<row><cell>2. Stack monitor</cell><cell></cell><cell>(1000)</cell>
</row>
<row><cell>3. Dust monitor</cell><cell></cell><cell>(200)</cell>
</row>
<row><cell>4. mobile monitor</cell><cell></cell><cell>no estimate</cell>
</row>
<row><cell>5. Alarm system</cell><cell></cell><cell>no estimate</cell>
</row>
<row><cell>(6. Console</cell><cell></cell><cell>no estimate )</cell>
</row>
<row><cell>7. Liquid monitor</cell><cell></cell><cell>(2500)</cell>
</row>
<row><cell>8. Log channel  </cell><cell>submitted to <name type="corporate">Nuclear <abbr expan="Instrument">Inst</abbr></name></cell><cell>?</cell>
</row>
<row><cell>9. Indium foils</cell><cell></cell><cell>no estimate</cell>
</row>
<row><cell cols='3'>10. Recombiner and disposal system (<name type="person">Menius</name> and <name type="person">Murray</name>)</cell>
</row>
<row><cell>11. Gas masks</cell><cell></cell><cell>(300)</cell>
</row>
<row><cell>General</cell><cell></cell><cell></cell>
</row>
<row><cell cols='2'>Interlocks, light panel, and hook up</cell><cell>(1500)</cell>
</row>
</table>