Attention is directed to the fact, that when the representatives
of the
company
they told us that the motors were designed for operation with
the shafts in a horizontal position. They were dubious of the
satisfactory operation of these motors with their shafts oriented
vertically. This matter was discussed at the time and the verdict
was to leave the mechanism unchanged until after criticallity
had been achieved, so that the change would not delay this
procedure.
Now that critically has been achieved, it is recommended
that the advice of the
that the mechanism be so modified that these motors operate
in their normal horizontal shaft position.
It is important that this be done as soon as possible
before activation of parts makes a long "cooling off" time
necessary.